Guide
Voids develop when space opens beneath concrete or within the ground supporting it. Soil may settle away from the slab, or water may transport material through a damaged pipe or drainage path. The cavity can remain hidden until the surface drops or a hole appears. A visible opening gives little certainty about the size of the affected area. This guide explains the evidence that helps distinguish a local loss of contact from a more extensive ground problem.
Pipes and trenches create interfaces with surrounding ground. When soil around a leaking asset becomes saturated or fines can enter a broken drain, support can diminish over time. A low spot following the line of a trench is useful evidence. A cavity next to a service also creates constraints on probing, excavation or injection. Find and assess the buried asset before treating the area.
A slab can bridge a cavity wider than the opening visible at its boundary. Likewise, a broad damp patch can point to little loss of material. It takes site evidence to determine which situation applies. Record changes from a safe position and limit loading until the condition is assessed. Concrete repair plans need to address how support will be restored and whether the original source of soil movement has been controlled.
A loose corner can move under a passing wheel long before the top surface presents a conspicuous hole. Local edge impact and muddy residue can be clues. Treat observable movement as evidence to investigate. Avoid deliberately loading the area to find the limits of the void, especially where the likely extent is unknown.
A cavity needs to be assessed for continuing soil loss. Fresh sediment at a drain, repeated depressions or movement after rain can suggest that water still has a route through the fill. The point where material emerges may be some distance from the original leak. Investigation should connect those observations before the void is filled. The proposed repair then needs to explain how the failed service or escape route will be addressed and how the remaining ground will be supported.
Empty space is only one possible defect beneath a slab. The material around a void may also be loose or compressible, leaving the repair with a wider support problem. A cavity fill specification should distinguish the volume to be occupied from any soil improvement required. The loads above matter too. A path and a building footing place different demands on the ground. The investigation needs enough evidence to relate the proposed treatment to those demands and the depth of the affected zone.
Depending on access and construction, investigation can include checking drainage, examining exposed edges, reviewing construction records or surveying the surface. Other methods may be considered by the relevant specialist. No single method resolves every hidden cavity. Link each proposed check to a question about the source, boundary, depth or remaining support.
Historic plans, service repairs and earlier photographs can help locate the ground disturbance behind a new depression. Their usefulness depends on how closely they relate to the affected area. Where boundaries remain uncertain, the relevant specialist may recommend further investigation. The findings should establish the source, extent and depth of the defect sufficiently to choose a repair. If a wider instability is suspected, the assessment needs to extend beyond the visible cavity before reinstatement is planned.
Unknown voids and buried services both constrain how a site can be investigated. Provide available utility information and keep people and vehicles away from suspect ground. Locating and access arrangements must suit the actual risk, including any affected road, retaining wall or foundation. Records of private plumbing can be incomplete, making additional checks necessary. Before treatment, identify which areas can be approached safely and how the work zone will be isolated from occupants, deliveries and neighbouring activities.
An injection material follows the spaces and resistance it encounters beneath the surface. Expanding resin also changes as it reacts, so placement depends on confinement and site conditions. A connected drain or trench can offer an unintended route. The repair plan should identify those possibilities and specify how progress will be assessed. Unexpected uptake needs interpretation against the intended zone. The amount injected alone gives limited evidence that a hidden cavity has been filled in the right place.
Resin injection may form part of a repair to a defined void. See sinkholes and washouts for the steps involved in investigating active ground loss. Slab jacking applies to suitable settled concrete, while underpinning concerns building foundations affected by the problem. Injection waterproofing addresses identified concrete leak paths. These services can overlap on a site, so treatment should follow the investigation findings.
For an enquiry about a suspected void, call The Lifting Specialists on 0414 799 325 from a safe location. Explain what you can see and which structures or routes are nearby. The guides to sinkholes and washouts and why concrete slabs sink provide additional background while an appropriate assessment is arranged.
Request a site inspection
Tell us what has changed at your property – a few photos help.
Prefer to talk? Call us
Tell us what has changed at your property and we can discuss the next step, including any investigation needed before treatment begins.